Michal P
Guest

Do you think giving a bolus of bicarbonate (10 mL) and looking at EtCO2 would help confirm the cannula is in the vein rather than in artery? I use this method from time to time with central lines.
Great (new) blog, congratulations.

Joseph Bellezzo
Editor
I haven’t tried it. Unlikely to be helpful in the arrested patient though. In fact, I know of no really good way to confirm line location during arrest. If pulses temporarily return I do use the bubble test – but that doesn’t help with finding the artery – which is the holy grail during arrest. I admit that there times when we aren’t 100% sure and only discover an inadvertent veno-venous cannulation after the pump is turned on. In that situation I’d stop the pump and continue to attempt to cannulate an artery. IF you do that, DON’T pull the… Read more »
Michal P
Guest

Thank you very much.
Maybe next time you’re cannulating please do try this test – just to prove me wrong. I’ll be more than happy to know the result.

Ari Kestler
Guest

What about istat gases off both lines? Or not helpful in arrest phase since likely very similar?

What do you think you are cannulating if you inadvertently VV someone? I assume you’ve placed 2 lines next to each other so deep and superficial femoral vein? Instead do common femoral vein and fem art?

Joseph Bellezzo
Editor
Great thoughts. We’ve tried iStat gasses/ABGs. Still too similar to truly distinguish, especially after prolonged arrest. In reality there often isn’t that much time. The most common problem is VV cannulation. Its almost never AA cannulation. Exactly which Vein? not clear but likely both in the common femoral vein one above the other. Sometimes you just aren’t sure and the patient is dying in front of you. A brief trial on the pump will usually unveil the inadvertent VV cannulation and there is no real harm…other than delay of VA ECMO, to temporary VV ECMO. If you turn on the… Read more »